C13 TO C14 POWER CABLE

C13 to C14 power cable

C13 to C14 power cable

Blog Article

C13 to C14 power cable is a standard type of electrical cable used to connect devices with a C14 inlet (female connector) to a power source or distribution unit with a C13 outlet (male connector). Here’s a detailed breakdown:



Key Features



  1. Connectors:

    • C13 (Outlet/Female): Found on devices like computers, monitors, servers, and network equipment. It accepts the C14 plug.

    • C14 (Plug/Male): Connects to power sources such as power strips, UPS units, or wall outlets (via an adapter).



  2. Voltage/Current Rating:

    • Typically rated for 10A at 250V (or 15A at 125V in North America), suitable for most IT and office equipment.



  3. Cable Length:

    • Available in various lengths (e.g., 0.5m, 1m, 1.5m, 3m) to suit different setups.



  4. Wire Gauge:

    • Commonly uses 18 AWG (for shorter lengths) or 16 AWG (for longer runs to reduce voltage drop).



  5. Color Options:

    • Often black, but may come in other colors (e.g., blue, gray) for organizational purposes.




Common Uses



  • Connecting servers, switches, or routers to a PDU (Power Distribution Unit) or UPS.

  • Linking monitors, printers, or desktop computers to a power strip.

  • Data center and rack-mounted equipment power distribution.


Safety & Standards



  • Certifications: Look for cables compliant with IEC 60320 and regional safety standards (e.g., UL, CE).

  • Polarity: Ensure the cable is wired correctly (hot, neutral, ground) to avoid damage.

  • Avoid Overloading: Do not exceed the cable’s current rating to prevent overheating.


Where to Buy



  • Online Retailers: Amazon, Newegg, Alibaba, or specialized IT suppliers (e.g., StarTech, Tripp Lite).

  • Local Electronics Stores: Check for availability at computer or office supply shops.

  • Manufacturers: Directly from brands like APC, Belkin, or C2G.


Alternatives



  • If you need a longer reach or higher current capacity, consider:

    • C19 to C20 cables (for higher-power devices like blade servers).

    • Locking connectors (e.g., C13 to C15 with a clip) for secure connections in vibrating environments.




Example Use Case



  • Scenario: You have a rack of servers with C14 inlets and need to connect them to a PDU with C13 outlets.

  • Solution: Use a C13 to C14 cable (e.g., 1.5m length) for each server.


Visual Reference



  • The C13 connector is the "kettle plug" shape (often on devices), while the C14 is the corresponding inlet (on cables or power sources).


If you need a specific length, color, or certification, specify your requirements when purchasing. Always verify compatibility with your devices and power sources!